1. Visual Inspection
Each pump is examined for external damage, cracks, and signs of wear on the body and components. Cosmetic issues and potential safety concerns are noted for further action.
Fully Refurbished
1-Year Warranty
Biomed Tested & Calibrated
Complete Working System
Abbott Hospira Plum A+ Infusion IV Pump
Refurbished • 1-Year Warranty • Cassette-based single-channel, dual-line volumetric infusion pump
The Hospira Plum A+ Infusion Pump is a cassette-based, single-channel volumetric infusion system with two fluid inputs and one common patient line. It supports standard, automated secondary piggyback, and concurrent infusion workflows using compatible LifeCare Plum series administration sets.
Fully refurbished and backed by a 1-year United Infusion warranty, the Plum A+ combines cassette-based volumetric delivery with primary and secondary infusion capability. The Plum cassette supports automated secondary delivery, concurrent infusion of compatible therapies, direct syringe connection, anti-free-flow protection, proximal and distal air detection, and backpriming for removal of air or fluid from the proximal tubing and cassette air trap.
| Manufacturer | Hospira, Inc. |
| Current Documentation / Support | ICU Medical |
| Model | Plum A+ Volumetric Infusion System |
| Device Configuration | Pump list number, software version, and network module vary by configuration. Verify the rear barcode label and installed software before selecting documentation. |
| Type | Cassette-based single-channel, dual-line volumetric infusion pump |
| Fluid Path | Two lines in — primary Line A and secondary Line B — with one common patient line out |
| Delivery Modes | Standard, automated secondary piggyback, and concurrent delivery |
| Delivery Rate | 0.1–99.9 mL/h in 0.1 mL/h increments; 100–999 mL/h in 1 mL/h increments |
| Delivery Accuracy | ≤±5% volumetric delivery-rate error from 1–999 mL/h over 48 hours during normal operating conditions; ≤±10% below 1 mL/h. Backpressure, filling head, concurrent delivery, and other operating conditions can affect accuracy. |
| Concurrent Delivery | Minimum 0.5 mL/h for each line; maximum combined Line A + Line B delivery rate of 500 mL/h |
| VTBI Range | 0.1–99.9 mL in 0.1 mL increments; 100–9,999 mL in 1 mL increments |
| KVO | 1.0 mL/h or the last primary delivery rate, whichever is lower |
| Administration Sets | Compatible LifeCare Plum series administration sets |
| Secondary Syringe Delivery | Syringes must be larger than 3 cc. Use of a syringe adapter depends on syringe size; syringes larger than 10 cc may attach directly to the cassette secondary port. |
| Air Management | Cassette air trap with proximal and distal air detection; backpriming supports removal of air or fluid from the proximal tubing and cassette air trap. |
| Occlusion Monitoring | Proximal and distal occlusion alarms; formal device specification lists a user-selectable distal pressure limit from 1–15 psig with a factory default of 6 psig. |
| Maximum Infusion Pressure | 20 psig |
| Dimensions | Approximately 8″ × 8″ × 6″, excluding pole-clamp protrusion and power-cord storage |
| Weight | Approximately 9.5 lb with battery |
| Power | 100–120 VAC, 50–60 Hz, 50 VA |
| Battery | One internal rechargeable 6 V sealed lead-acid battery |
| Published Battery Operation | Intended for emergency backup and temporary portable operation. With a new, fully charged battery: minimum 3 hours of operation at 125 mL/h or less, or a 250 mL total-volume criterion at higher delivery rates, whichever occurs first. Actual runtime depends on battery age, condition, configuration, wireless use, and operating conditions. |
| Battery Recharge | Approximately 6 hours while connected to AC power with the device operating at 125 mL/h on one line. Recharge can take longer under other operating conditions. |
| Nurse Call | Rear Nurse Call relay connector for compatible remote-notification systems |
| Connectivity | Ethernet and IEEE 802.11 a/b/g wireless networking on compatible Hospira MedNet-equipped configurations |
| Condition | Refurbished |
| Warranty | 1-Year United Infusion warranty |
View the current official U.S. Plum A+ documentation hosted by ICU Medical.
ICU Medical’s current U.S. manual index lists manual 430-95597-010, revision 06/2015, for the Plum A+ MedNet Plug ’n Play wireless configuration with software v13.x and 802.11 a/b/g. The manual itself applies to specific Plum A+ pump list numbers and module configurations. Verify the pump list number on the rear barcode label and the installed software/network configuration before selecting or using documentation.
Fully Refurbished
1-Year Warranty
Biomed Tested & Calibrated
Complete Working System
Abbott Hospira Plum A+ Infusion IV Pump
Refurbished • 1-Year Warranty • Cassette-based single-channel, dual-line volumetric infusion pump
The Hospira Plum A+ Infusion Pump is a cassette-based, single-channel volumetric infusion system with two fluid inputs and one common patient line. It supports standard, automated secondary piggyback, and concurrent infusion workflows using compatible LifeCare Plum series administration sets.
Fully refurbished and backed by a 1-year United Infusion warranty, the Plum A+ combines cassette-based volumetric delivery with primary and secondary infusion capability. The Plum cassette supports automated secondary delivery, concurrent infusion of compatible therapies, direct syringe connection, anti-free-flow protection, proximal and distal air detection, and backpriming for removal of air or fluid from the proximal tubing and cassette air trap.
| Manufacturer | Hospira, Inc. |
| Current Documentation / Support | ICU Medical |
| Model | Plum A+ Volumetric Infusion System |
| Device Configuration | Pump list number, software version, and network module vary by configuration. Verify the rear barcode label and installed software before selecting documentation. |
| Type | Cassette-based single-channel, dual-line volumetric infusion pump |
| Fluid Path | Two lines in — primary Line A and secondary Line B — with one common patient line out |
| Delivery Modes | Standard, automated secondary piggyback, and concurrent delivery |
| Delivery Rate | 0.1–99.9 mL/h in 0.1 mL/h increments; 100–999 mL/h in 1 mL/h increments |
| Delivery Accuracy | ≤±5% volumetric delivery-rate error from 1–999 mL/h over 48 hours during normal operating conditions; ≤±10% below 1 mL/h. Backpressure, filling head, concurrent delivery, and other operating conditions can affect accuracy. |
| Concurrent Delivery | Minimum 0.5 mL/h for each line; maximum combined Line A + Line B delivery rate of 500 mL/h |
| VTBI Range | 0.1–99.9 mL in 0.1 mL increments; 100–9,999 mL in 1 mL increments |
| KVO | 1.0 mL/h or the last primary delivery rate, whichever is lower |
| Administration Sets | Compatible LifeCare Plum series administration sets |
| Secondary Syringe Delivery | Syringes must be larger than 3 cc. Use of a syringe adapter depends on syringe size; syringes larger than 10 cc may attach directly to the cassette secondary port. |
| Air Management | Cassette air trap with proximal and distal air detection; backpriming supports removal of air or fluid from the proximal tubing and cassette air trap. |
| Occlusion Monitoring | Proximal and distal occlusion alarms; formal device specification lists a user-selectable distal pressure limit from 1–15 psig with a factory default of 6 psig. |
| Maximum Infusion Pressure | 20 psig |
| Dimensions | Approximately 8″ × 8″ × 6″, excluding pole-clamp protrusion and power-cord storage |
| Weight | Approximately 9.5 lb with battery |
| Power | 100–120 VAC, 50–60 Hz, 50 VA |
| Battery | One internal rechargeable 6 V sealed lead-acid battery |
| Published Battery Operation | Intended for emergency backup and temporary portable operation. With a new, fully charged battery: minimum 3 hours of operation at 125 mL/h or less, or a 250 mL total-volume criterion at higher delivery rates, whichever occurs first. Actual runtime depends on battery age, condition, configuration, wireless use, and operating conditions. |
| Battery Recharge | Approximately 6 hours while connected to AC power with the device operating at 125 mL/h on one line. Recharge can take longer under other operating conditions. |
| Nurse Call | Rear Nurse Call relay connector for compatible remote-notification systems |
| Connectivity | Ethernet and IEEE 802.11 a/b/g wireless networking on compatible Hospira MedNet-equipped configurations |
| Condition | Refurbished |
| Warranty | 1-Year United Infusion warranty |
View the current official U.S. Plum A+ documentation hosted by ICU Medical.
ICU Medical’s current U.S. manual index lists manual 430-95597-010, revision 06/2015, for the Plum A+ MedNet Plug ’n Play wireless configuration with software v13.x and 802.11 a/b/g. The manual itself applies to specific Plum A+ pump list numbers and module configurations. Verify the pump list number on the rear barcode label and the installed software/network configuration before selecting or using documentation.
Abbott Hospira Plum A+ Infusion IV Pump
Refurbished • 1-Year Warranty • Cassette-based single-channel, dual-line volumetric infusion pump
The Hospira Plum A+ Infusion Pump is a cassette-based, single-channel volumetric infusion system with two fluid inputs and one common patient line. It supports standard, automated secondary piggyback, and concurrent infusion workflows using compatible LifeCare Plum series administration sets.
Fully refurbished and backed by a 1-year United Infusion warranty, the Plum A+ combines cassette-based volumetric delivery with primary and secondary infusion capability. The Plum cassette supports automated secondary delivery, concurrent infusion of compatible therapies, direct syringe connection, anti-free-flow protection, proximal and distal air detection, and backpriming for removal of air or fluid from the proximal tubing and cassette air trap.
| Manufacturer | Hospira, Inc. |
| Current Documentation / Support | ICU Medical |
| Model | Plum A+ Volumetric Infusion System |
| Device Configuration | Pump list number, software version, and network module vary by configuration. Verify the rear barcode label and installed software before selecting documentation. |
| Type | Cassette-based single-channel, dual-line volumetric infusion pump |
| Fluid Path | Two lines in — primary Line A and secondary Line B — with one common patient line out |
| Delivery Modes | Standard, automated secondary piggyback, and concurrent delivery |
| Delivery Rate | 0.1–99.9 mL/h in 0.1 mL/h increments; 100–999 mL/h in 1 mL/h increments |
| Delivery Accuracy | ≤±5% volumetric delivery-rate error from 1–999 mL/h over 48 hours during normal operating conditions; ≤±10% below 1 mL/h. Backpressure, filling head, concurrent delivery, and other operating conditions can affect accuracy. |
| Concurrent Delivery | Minimum 0.5 mL/h for each line; maximum combined Line A + Line B delivery rate of 500 mL/h |
| VTBI Range | 0.1–99.9 mL in 0.1 mL increments; 100–9,999 mL in 1 mL increments |
| KVO | 1.0 mL/h or the last primary delivery rate, whichever is lower |
| Administration Sets | Compatible LifeCare Plum series administration sets |
| Secondary Syringe Delivery | Syringes must be larger than 3 cc. Use of a syringe adapter depends on syringe size; syringes larger than 10 cc may attach directly to the cassette secondary port. |
| Air Management | Cassette air trap with proximal and distal air detection; backpriming supports removal of air or fluid from the proximal tubing and cassette air trap. |
| Occlusion Monitoring | Proximal and distal occlusion alarms; formal device specification lists a user-selectable distal pressure limit from 1–15 psig with a factory default of 6 psig. |
| Maximum Infusion Pressure | 20 psig |
| Dimensions | Approximately 8″ × 8″ × 6″, excluding pole-clamp protrusion and power-cord storage |
| Weight | Approximately 9.5 lb with battery |
| Power | 100–120 VAC, 50–60 Hz, 50 VA |
| Battery | One internal rechargeable 6 V sealed lead-acid battery |
| Published Battery Operation | Intended for emergency backup and temporary portable operation. With a new, fully charged battery: minimum 3 hours of operation at 125 mL/h or less, or a 250 mL total-volume criterion at higher delivery rates, whichever occurs first. Actual runtime depends on battery age, condition, configuration, wireless use, and operating conditions. |
| Battery Recharge | Approximately 6 hours while connected to AC power with the device operating at 125 mL/h on one line. Recharge can take longer under other operating conditions. |
| Nurse Call | Rear Nurse Call relay connector for compatible remote-notification systems |
| Connectivity | Ethernet and IEEE 802.11 a/b/g wireless networking on compatible Hospira MedNet-equipped configurations |
| Condition | Refurbished |
| Warranty | 1-Year United Infusion warranty |
View the current official U.S. Plum A+ documentation hosted by ICU Medical.
ICU Medical’s current U.S. manual index lists manual 430-95597-010, revision 06/2015, for the Plum A+ MedNet Plug ’n Play wireless configuration with software v13.x and 802.11 a/b/g. The manual itself applies to specific Plum A+ pump list numbers and module configurations. Verify the pump list number on the rear barcode label and the installed software/network configuration before selecting or using documentation.
At United Infusion, we follow a comprehensive refurbishing process for infusion pumps to help ensure they operate safely and reliably. This process follows manufacturer guidelines and sanitation standards to meet high quality expectations.
Below are the key steps of our refurbishing process:
Each pump is examined for external damage, cracks, and signs of wear on the body and components. Cosmetic issues and potential safety concerns are noted for further action.
The pump is carefully disassembled to access internal components, including the motor, gears, tubing pathways, and electronics. All parts are handled with care to avoid added damage.
Appropriate disinfectants are used to thoroughly clean all parts and remove residual fluids, blood, or debris. This step follows sanitation standards to help ensure the device is free from contaminants.
Individual parts, including the motor, battery, display screen, buttons, and connectors, are inspected for wear, damage, or malfunction. Worn or damaged components are replaced with manufacturer-approved parts.
The pump is adjusted to support accurate fluid delivery rates using standardized testing methods, and calibration is verified against manufacturer specifications. The latest compatible software version is then installed to improve functionality.
The pump goes through functional testing, including alarms, flow rate accuracy, occlusion detection, and bolus delivery. It is then reassembled, connections are checked, and a final visual and functional inspection is completed to confirm it meets safety standards and customer requirements.
"We needed our syringe pumps serviced for scheduled maintenance to continue to provide safe care. In the past, we had to send them off with a 6 weeks turn around time. Then we found United Infusion. 30 min down the road, 24 hr turn around and 30 minutes down the road. We are extremely grateful!!!"
United Infusion supports equipment sales, repair, and rentals. Our team can help match the right unit, answer product questions, and support your equipment needs.