- Volumetric infusion pump with 0.1–800.0 mL/hr published flow-rate range using approved Vista tubing
- Continuous, Piggyback, Program, Ramp/Taper, and Delay A modes
- Refurbished • Tested and Calibrated • 1-Year Warranty Included
Refurbished B. Braun Vista Basic Infusion Pump
Refurbished • 1-Year Warranty Included • Volumetric Infusion Pump • United Infusion SKU 637-202U Vista Basic
The B. Braun Vista Basic is a linear peristaltic volumetric infusion pump intended to provide controlled flow of parenteral and enteral fluids using compatible B. Braun Vista administration sets. Manufacturer documentation supports Continuous and Piggyback delivery as well as Program, Ramp/Taper, and Delay A operating modes.
What’s Included
- 1× refurbished B. Braun Vista Basic Infusion Pump
Configuration note: Power cord, pole clamp, drop sensor, administration sets, installed battery type, and other accessories should be treated as configuration-dependent unless specifically confirmed with the unit.
Product Description
The Vista Basic uses a linear peristaltic pumping mechanism with approved Vista administration sets. The manufacturer-published delivery range is 0.1 to 800.0 mL/hr in 0.1 mL/hr increments with Vista tubing, with a volume-to-be-infused range of 0.1 to 9999.9 mL.
B. Braun documentation supports Continuous and Piggyback modes, Program Mode for variable-rate infusions, Ramp/Taper Mode for TPN infusions, and Delay A Mode for postponing infusion start and finish. The pump also provides air-in-line detection, downstream occlusion monitoring, KVO operation, battery operation, and audible and visual alarm functions.
- Linear peristaltic volumetric pumping mechanism
- 0.1–800.0 mL/hr published rate range with approved Vista tubing
- 0.1–9999.9 mL volume-to-be-infused range
- Published flow-rate accuracy of ±5% under the manufacturer's stated test conditions with approved Vista tubing
- Continuous and Piggyback infusion modes
- Program Mode for variable-rate infusions
- Ramp/Taper Mode for TPN infusions
- Delay A Mode for postponing infusion start and finish
- Low and high downstream occlusion-pressure settings
- Air-in-line, low-battery, downstream-occlusion, door-open, KVO, and equipment alarms
- Empty-container and upstream-occlusion detection when the optional drop-sensor function is used
- Pump- and set-based free-flow protection with applicable Vista Basic administration sets
Administration-set note: Use administration sets intended for the Vista Basic and verify the exact set catalog number before use. B. Braun's current U.S. product page continues to list Vista Basic pump sets and describes pump- and set-based free-flow protection.
Current safety note: FDA currently lists an open Class II recall involving specific B. Braun administration sets used with the Vista Basic and other B. Braun infusion pumps. The affected records include Vista Basic Pump IV Set catalog US9923F and concern potential secondary-medication backflow and difficulty priming. The FDA record applies to the specified administration set, not to the Vista Basic pump itself. Verify the catalog number and current recall status of administration sets before use.
Specifications — B. Braun Vista Basic
| Manufacturer | B. Braun Medical Inc. |
| Product | Vista Basic Infusion Pump |
| United Infusion SKU | 637-202U Vista Basic |
| Documented Vista Basic Device Numbers | 637-102 and 637-202; verify the exact device number on the refurbished unit label |
| Pump Type | Linear peristaltic volumetric infusion pump |
| Intended Fluid Delivery | Parenteral and enteral fluids |
| Published Rate Range | 0.1–800.0 mL/hr in 0.1 mL/hr increments with approved Vista tubing |
| VTBI Range | 0.1–9999.9 mL |
| Published Flow Accuracy | ±5% over an 8-hour measurement period at 71.6°F (22°C), using approved Vista tubing |
| Occlusion Pressure | Low: 8 PSI • High: 17 PSI |
| KVO Rate | 1 mL/hr or the selected infusion rate, whichever is lower |
| Infusion Modes | Continuous, Piggyback, Program, Ramp/Taper, and Delay A |
| Administration Sets | B. Braun Vista administration sets; verify exact catalog number and current safety status before use |
| Power Requirements | 100–120 VAC, 50–60 Hz, 13 W |
| Legacy Manufacturer Battery Specification | 7.2 V, 1.2 Ah rechargeable NiCd; verify the battery installed in the refurbished unit |
| Published Battery Operating Time | Approximately 3.5 hours at 125 mL/hr with the manufacturer-specified battery; actual refurbished-unit runtime depends on the installed battery's type, age, condition, and use |
| Published Battery Recharge Time | Approximately 16 hours |
| Dimensions | 5.5 × 9.4 × 7.8 in (W × H × D) |
| Weight | 6.8 lb (3.1 kg) |
| Condition | Refurbished |
| Seller Warranty | 1-Year Warranty Included |
Product Documentation
B. Braun's current U.S. page confirms Vista Basic administration-set support. The legacy manufacturer-authored Instructions for Use is provided for pump-specific operating and technical information. Verify the exact device number and configuration before using legacy documentation for service or operation.
Fully Refurbished
1-Year Warranty
Biomed Tested & Calibrated
Complete Working System
- Volumetric infusion pump with 0.1–800.0 mL/hr published flow-rate range using approved Vista tubing
- Continuous, Piggyback, Program, Ramp/Taper, and Delay A modes
- Refurbished • Tested and Calibrated • 1-Year Warranty Included
Refurbished B. Braun Vista Basic Infusion Pump
Refurbished • 1-Year Warranty Included • Volumetric Infusion Pump • United Infusion SKU 637-202U Vista Basic
The B. Braun Vista Basic is a linear peristaltic volumetric infusion pump intended to provide controlled flow of parenteral and enteral fluids using compatible B. Braun Vista administration sets. Manufacturer documentation supports Continuous and Piggyback delivery as well as Program, Ramp/Taper, and Delay A operating modes.
What’s Included
- 1× refurbished B. Braun Vista Basic Infusion Pump
Configuration note: Power cord, pole clamp, drop sensor, administration sets, installed battery type, and other accessories should be treated as configuration-dependent unless specifically confirmed with the unit.
Product Description
The Vista Basic uses a linear peristaltic pumping mechanism with approved Vista administration sets. The manufacturer-published delivery range is 0.1 to 800.0 mL/hr in 0.1 mL/hr increments with Vista tubing, with a volume-to-be-infused range of 0.1 to 9999.9 mL.
B. Braun documentation supports Continuous and Piggyback modes, Program Mode for variable-rate infusions, Ramp/Taper Mode for TPN infusions, and Delay A Mode for postponing infusion start and finish. The pump also provides air-in-line detection, downstream occlusion monitoring, KVO operation, battery operation, and audible and visual alarm functions.
- Linear peristaltic volumetric pumping mechanism
- 0.1–800.0 mL/hr published rate range with approved Vista tubing
- 0.1–9999.9 mL volume-to-be-infused range
- Published flow-rate accuracy of ±5% under the manufacturer's stated test conditions with approved Vista tubing
- Continuous and Piggyback infusion modes
- Program Mode for variable-rate infusions
- Ramp/Taper Mode for TPN infusions
- Delay A Mode for postponing infusion start and finish
- Low and high downstream occlusion-pressure settings
- Air-in-line, low-battery, downstream-occlusion, door-open, KVO, and equipment alarms
- Empty-container and upstream-occlusion detection when the optional drop-sensor function is used
- Pump- and set-based free-flow protection with applicable Vista Basic administration sets
Administration-set note: Use administration sets intended for the Vista Basic and verify the exact set catalog number before use. B. Braun's current U.S. product page continues to list Vista Basic pump sets and describes pump- and set-based free-flow protection.
Current safety note: FDA currently lists an open Class II recall involving specific B. Braun administration sets used with the Vista Basic and other B. Braun infusion pumps. The affected records include Vista Basic Pump IV Set catalog US9923F and concern potential secondary-medication backflow and difficulty priming. The FDA record applies to the specified administration set, not to the Vista Basic pump itself. Verify the catalog number and current recall status of administration sets before use.
Specifications — B. Braun Vista Basic
| Manufacturer | B. Braun Medical Inc. |
| Product | Vista Basic Infusion Pump |
| United Infusion SKU | 637-202U Vista Basic |
| Documented Vista Basic Device Numbers | 637-102 and 637-202; verify the exact device number on the refurbished unit label |
| Pump Type | Linear peristaltic volumetric infusion pump |
| Intended Fluid Delivery | Parenteral and enteral fluids |
| Published Rate Range | 0.1–800.0 mL/hr in 0.1 mL/hr increments with approved Vista tubing |
| VTBI Range | 0.1–9999.9 mL |
| Published Flow Accuracy | ±5% over an 8-hour measurement period at 71.6°F (22°C), using approved Vista tubing |
| Occlusion Pressure | Low: 8 PSI • High: 17 PSI |
| KVO Rate | 1 mL/hr or the selected infusion rate, whichever is lower |
| Infusion Modes | Continuous, Piggyback, Program, Ramp/Taper, and Delay A |
| Administration Sets | B. Braun Vista administration sets; verify exact catalog number and current safety status before use |
| Power Requirements | 100–120 VAC, 50–60 Hz, 13 W |
| Legacy Manufacturer Battery Specification | 7.2 V, 1.2 Ah rechargeable NiCd; verify the battery installed in the refurbished unit |
| Published Battery Operating Time | Approximately 3.5 hours at 125 mL/hr with the manufacturer-specified battery; actual refurbished-unit runtime depends on the installed battery's type, age, condition, and use |
| Published Battery Recharge Time | Approximately 16 hours |
| Dimensions | 5.5 × 9.4 × 7.8 in (W × H × D) |
| Weight | 6.8 lb (3.1 kg) |
| Condition | Refurbished |
| Seller Warranty | 1-Year Warranty Included |
Product Documentation
B. Braun's current U.S. page confirms Vista Basic administration-set support. The legacy manufacturer-authored Instructions for Use is provided for pump-specific operating and technical information. Verify the exact device number and configuration before using legacy documentation for service or operation.
- Volumetric infusion pump with 0.1–800.0 mL/hr published flow-rate range using approved Vista tubing
- Continuous, Piggyback, Program, Ramp/Taper, and Delay A modes
- Refurbished • Tested and Calibrated • 1-Year Warranty Included
Refurbished B. Braun Vista Basic Infusion Pump
Refurbished • 1-Year Warranty Included • Volumetric Infusion Pump • United Infusion SKU 637-202U Vista Basic
The B. Braun Vista Basic is a linear peristaltic volumetric infusion pump intended to provide controlled flow of parenteral and enteral fluids using compatible B. Braun Vista administration sets. Manufacturer documentation supports Continuous and Piggyback delivery as well as Program, Ramp/Taper, and Delay A operating modes.
What’s Included
- 1× refurbished B. Braun Vista Basic Infusion Pump
Configuration note: Power cord, pole clamp, drop sensor, administration sets, installed battery type, and other accessories should be treated as configuration-dependent unless specifically confirmed with the unit.
Product Description
The Vista Basic uses a linear peristaltic pumping mechanism with approved Vista administration sets. The manufacturer-published delivery range is 0.1 to 800.0 mL/hr in 0.1 mL/hr increments with Vista tubing, with a volume-to-be-infused range of 0.1 to 9999.9 mL.
B. Braun documentation supports Continuous and Piggyback modes, Program Mode for variable-rate infusions, Ramp/Taper Mode for TPN infusions, and Delay A Mode for postponing infusion start and finish. The pump also provides air-in-line detection, downstream occlusion monitoring, KVO operation, battery operation, and audible and visual alarm functions.
- Linear peristaltic volumetric pumping mechanism
- 0.1–800.0 mL/hr published rate range with approved Vista tubing
- 0.1–9999.9 mL volume-to-be-infused range
- Published flow-rate accuracy of ±5% under the manufacturer's stated test conditions with approved Vista tubing
- Continuous and Piggyback infusion modes
- Program Mode for variable-rate infusions
- Ramp/Taper Mode for TPN infusions
- Delay A Mode for postponing infusion start and finish
- Low and high downstream occlusion-pressure settings
- Air-in-line, low-battery, downstream-occlusion, door-open, KVO, and equipment alarms
- Empty-container and upstream-occlusion detection when the optional drop-sensor function is used
- Pump- and set-based free-flow protection with applicable Vista Basic administration sets
Administration-set note: Use administration sets intended for the Vista Basic and verify the exact set catalog number before use. B. Braun's current U.S. product page continues to list Vista Basic pump sets and describes pump- and set-based free-flow protection.
Current safety note: FDA currently lists an open Class II recall involving specific B. Braun administration sets used with the Vista Basic and other B. Braun infusion pumps. The affected records include Vista Basic Pump IV Set catalog US9923F and concern potential secondary-medication backflow and difficulty priming. The FDA record applies to the specified administration set, not to the Vista Basic pump itself. Verify the catalog number and current recall status of administration sets before use.
Specifications — B. Braun Vista Basic
| Manufacturer | B. Braun Medical Inc. |
| Product | Vista Basic Infusion Pump |
| United Infusion SKU | 637-202U Vista Basic |
| Documented Vista Basic Device Numbers | 637-102 and 637-202; verify the exact device number on the refurbished unit label |
| Pump Type | Linear peristaltic volumetric infusion pump |
| Intended Fluid Delivery | Parenteral and enteral fluids |
| Published Rate Range | 0.1–800.0 mL/hr in 0.1 mL/hr increments with approved Vista tubing |
| VTBI Range | 0.1–9999.9 mL |
| Published Flow Accuracy | ±5% over an 8-hour measurement period at 71.6°F (22°C), using approved Vista tubing |
| Occlusion Pressure | Low: 8 PSI • High: 17 PSI |
| KVO Rate | 1 mL/hr or the selected infusion rate, whichever is lower |
| Infusion Modes | Continuous, Piggyback, Program, Ramp/Taper, and Delay A |
| Administration Sets | B. Braun Vista administration sets; verify exact catalog number and current safety status before use |
| Power Requirements | 100–120 VAC, 50–60 Hz, 13 W |
| Legacy Manufacturer Battery Specification | 7.2 V, 1.2 Ah rechargeable NiCd; verify the battery installed in the refurbished unit |
| Published Battery Operating Time | Approximately 3.5 hours at 125 mL/hr with the manufacturer-specified battery; actual refurbished-unit runtime depends on the installed battery's type, age, condition, and use |
| Published Battery Recharge Time | Approximately 16 hours |
| Dimensions | 5.5 × 9.4 × 7.8 in (W × H × D) |
| Weight | 6.8 lb (3.1 kg) |
| Condition | Refurbished |
| Seller Warranty | 1-Year Warranty Included |
Product Documentation
B. Braun's current U.S. page confirms Vista Basic administration-set support. The legacy manufacturer-authored Instructions for Use is provided for pump-specific operating and technical information. Verify the exact device number and configuration before using legacy documentation for service or operation.
"We needed our syringe pumps serviced for scheduled maintenance to continue to provide safe care. In the past, we had to send them off with a 6 weeks turn around time. Then we found United Infusion. 30 min down the road, 24 hr turn around and 30 minutes down the road. We are extremely grateful!!!"
Need a quote, service help, or a similar model?
United Infusion supports equipment sales, repair, and rentals. Our team can help match the right unit, answer product questions, and support your equipment needs.