1. Visual Inspection
Each pump is examined for external damage, cracks, and signs of wear on the body and components. Cosmetic issues and potential safety concerns are noted for further action.
Refurbished by United Infusion
Tested and calibrated
1-Year Warranty Included
Service and repair support available
CareFusion Alaris Medley Module PCU 8015 (4.7″ Screen)
Refurbished and recertified Alaris 8015 PC Unit • 4.7-inch color display • Wireless-capable • 1-Year Warranty
The CareFusion Alaris Medley Module PCU 8015 is the central controller for the Alaris modular infusion system. Its 4.7-inch color display provides a common interface for programming compatible infusion modules and viewing system information. The PC Unit supports Guardrails Suite MX and can operate with up to four compatible infusion or monitoring modules. Modules are sold separately.
Fully refurbished, recertified, and backed by a 1-year warranty, the Alaris 8015 PC Unit serves as the core of an Alaris modular system used in adult, pediatric, and neonatal care. It supplies the shared color display, controls, power, and system communication for attached modules. The controller does not deliver an infusion by itself and requires compatible Alaris modules for infusion or patient-monitoring functions.
| Model | 8015 — Alaris PC Unit (Point-of-Care Unit) |
| Type | Central system controller for compatible Alaris infusion and monitoring modules |
| Display | 4.7-inch diagonal color screen |
| Dimensions | 6.9″ W × 8.8″ H × 9″ D (17.5 × 22.4 × 22.9 cm), including pole clamp |
| Weight | 7.2 lb (3.3 kg) |
| Module Capacity | Up to four infusion or monitoring modules; an Auto-ID Module may be included as a fifth module |
| Battery Operation | Up to 6 hours with one Pump Module infusing at 25 mL/h using a new, fully charged battery; runtime varies by attached modules and activity |
| Power Requirements | 100–240 V AC, 50/60 Hz, 150 VA maximum |
| Communication Data Port | RS-232 with RJ45 connector |
| Electronic Memory | Compact flash memory stores the system configuration, data set, and operating software; onboard flash memory stores event, error, and battery logs |
| Safety Software | Guardrails Suite MX compatible; data set, drug library, limits, and configuration vary by facility |
| Connectivity | Wireless-capable; network hardware and configuration may vary |
| Fluid Ingress Protection | IPX2, drip-proof |
| Patient Population | Adult, pediatric, and neonatal use as part of a configured Alaris System |
| Condition | Refurbished and recertified |
| Warranty | 1 year |
Download the official user manual for the Alaris System with the 8015 PC Unit.
Refurbished by United Infusion
Tested and calibrated
1-Year Warranty Included
Service and repair support available
CareFusion Alaris Medley Module PCU 8015 (4.7″ Screen)
Refurbished and recertified Alaris 8015 PC Unit • 4.7-inch color display • Wireless-capable • 1-Year Warranty
The CareFusion Alaris Medley Module PCU 8015 is the central controller for the Alaris modular infusion system. Its 4.7-inch color display provides a common interface for programming compatible infusion modules and viewing system information. The PC Unit supports Guardrails Suite MX and can operate with up to four compatible infusion or monitoring modules. Modules are sold separately.
Fully refurbished, recertified, and backed by a 1-year warranty, the Alaris 8015 PC Unit serves as the core of an Alaris modular system used in adult, pediatric, and neonatal care. It supplies the shared color display, controls, power, and system communication for attached modules. The controller does not deliver an infusion by itself and requires compatible Alaris modules for infusion or patient-monitoring functions.
| Model | 8015 — Alaris PC Unit (Point-of-Care Unit) |
| Type | Central system controller for compatible Alaris infusion and monitoring modules |
| Display | 4.7-inch diagonal color screen |
| Dimensions | 6.9″ W × 8.8″ H × 9″ D (17.5 × 22.4 × 22.9 cm), including pole clamp |
| Weight | 7.2 lb (3.3 kg) |
| Module Capacity | Up to four infusion or monitoring modules; an Auto-ID Module may be included as a fifth module |
| Battery Operation | Up to 6 hours with one Pump Module infusing at 25 mL/h using a new, fully charged battery; runtime varies by attached modules and activity |
| Power Requirements | 100–240 V AC, 50/60 Hz, 150 VA maximum |
| Communication Data Port | RS-232 with RJ45 connector |
| Electronic Memory | Compact flash memory stores the system configuration, data set, and operating software; onboard flash memory stores event, error, and battery logs |
| Safety Software | Guardrails Suite MX compatible; data set, drug library, limits, and configuration vary by facility |
| Connectivity | Wireless-capable; network hardware and configuration may vary |
| Fluid Ingress Protection | IPX2, drip-proof |
| Patient Population | Adult, pediatric, and neonatal use as part of a configured Alaris System |
| Condition | Refurbished and recertified |
| Warranty | 1 year |
Download the official user manual for the Alaris System with the 8015 PC Unit.
At United Infusion, we follow a comprehensive refurbishing process for infusion pumps to help ensure they operate safely and reliably. This process follows manufacturer guidelines and sanitation standards to meet high quality expectations.
Below are the key steps of our refurbishing process:
Each pump is examined for external damage, cracks, and signs of wear on the body and components. Cosmetic issues and potential safety concerns are noted for further action.
The pump is carefully disassembled to access internal components, including the motor, gears, tubing pathways, and electronics. All parts are handled with care to avoid added damage.
Appropriate disinfectants are used to thoroughly clean all parts and remove residual fluids, blood, or debris. This step follows sanitation standards to help ensure the device is free from contaminants.
Individual parts, including the motor, battery, display screen, buttons, and connectors, are inspected for wear, damage, or malfunction. Worn or damaged components are replaced with manufacturer-approved parts.
The pump is adjusted to support accurate fluid delivery rates using standardized testing methods, and calibration is verified against manufacturer specifications. The latest compatible software version is then installed to improve functionality.
The pump goes through functional testing, including alarms, flow rate accuracy, occlusion detection, and bolus delivery. It is then reassembled, connections are checked, and a final visual and functional inspection is completed to confirm it meets safety standards and customer requirements.
"We needed our syringe pumps serviced for scheduled maintenance to continue to provide safe care. In the past, we had to send them off with a 6 weeks turn around time. Then we found United Infusion. 30 min down the road, 24 hr turn around and 30 minutes down the road. We are extremely grateful!!!"
United Infusion supports equipment sales, repair, and rentals. Our team can help match the right unit, answer product questions, and support your equipment needs.